Digital Turbine Flowmeter Fuel Tester
Digital Turbine Flowmeter Fuel Tester Digital Turbine Flowmeter Fuel Tester Digital Turbine Flowmeter Fuel Tester Digital Turbine Flowmeter Fuel Tester Digital Turbine Flowmeter Fuel Tester

Digital Turbine Flowmeter Fuel Tester
2 reviews

SKU #6622832820260

Tip: Flow Meters & Controllers

Disponibilitate: In stoc

Prețuri începând de la: $ 55.19

LIVRARE GRATUITĂ ÎN LUME

Features:
Modular makes it suitable for use with output modules, sensors and remote transmitters.
Compact structure, easy to install.
Intuitive clear reading, high reliability, measuring accuracy is ±1%.
High-definition displays show both instantaneous and cumulative .
Can be widely used to measure , kerosene, gasoline, etc.

Specification:
Operating voltage:
2.3-3.3V
Battery type:
2 x AAA LRO3 batteries
Threadsize:
1inchNPT
Repetition:
±0.5%
Measure accuracy:
±1%
Maximum working pressure:
20BAR
range:
15-120L / Min
Single count:
0.00-9999.9
Total cumulative count:
0-99999
Mistakes count:
0.1000-9.9999
Working temperature:
-10°C ~ +60°C(14°F~140°F)
Standby time:
1 year
Application:
, kerosene, gasoline
Color:
Red, Blue?leave a message,or we will send by random
Weight:
371g

Malfunction and solution:
The meter is not accurate.
1. The method of field calibration is not correct.
Calibrate again.
2. The rate on the meter is below the lowest.
Increase the rate.
3. The meter is blocked by the dry liquid.
Take out the impeller and it carefully and make sure the impeller turns freely.
4. The impeller is wrapped by the sealing material.
Remove the meter and make sure the impeller turns freely.
5. Too close to the impeller.
Install properly.
6. Too close to the motor or electronic noise environment
Install properly.
The reading numbers faded or blanked out.
1.Battery is exhausted or not connected
Check the batteries or even replace them.
rate is normal but the meter can not count. Press the button of DISPLAY, the meter starts.
1. Field calibration is not correct.
Calibrate again.
2. The impeller is blocked or damaged.
Remove the meter and make sure the impeller turns freely.
3.The impeller is wrapped by the sealing material.
Remove the meter and make sure the impeller turns freely.
rate is low and the meter can not count. Press the button of DISPLAY, the meter starts.
1. The meter is blocked by the dry liquid.
Take out the impeller, it carefully and make sure the impeller turns freely.
2. The rate on the meter is below the lowest.
Increase the rate.
The meter can not calibrate.
1. Circuit board is break down.
Replace the circuit board.
2. Button is fail to press.
Replace the circuit board.

Package List:
1 x meter
1x Manual
Note:Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.



GARANȚIE

Vă vom rambursa banii dacă articolul nu a fost livrat în termen de 40 de zile de la cumpărare. Aveți la dispoziție 2 săptămâni pentru a solicita o rambursare - până în ziua 60.
Produsul nu se potrivește cu descrierea? Contactați-ne în termen de 30 de zile de la primire!
În caz de anulare, banii vor fi rambursați în contul dvs. în termen de 3 zile.

RECENZII


CL It Came Very Fast Works Super Well The Packaging Was Lousy But Arrived In Perfect Condition 17 Apr 2021 07:30
N***t from CHILE
UA 10 Jun 2021 01:09
G***r from UKRAINE